Which standard applies to Izod impact testing? ASTM D256 and ISO 180 are key standards associated with Izod testing, but the right choice depends on the material and the test requirement. The method uses a pendulum to strike a notched specimen held vertically; the machine records the energy absorbed as the specimen fractures or deforms.
Which standards apply to Izod impact testing?

For many plastics testing requirements, ASTM D256 and ISO 180 are the principal standards to check for an Izod method. The applicable standard and procedure depend on the material specification and what the test result must demonstrate.
Start with the material specification, customer requirement or quality-control procedure. It should identify the test method and may also define specimen preparation, conditioning, dimensions, notch details, test conditions and reporting requirements. Do not assume that any test labelled “Izod” automatically meets a particular specification.
The question “what is the standard for Izod impact testing?” therefore has a practical answer: identify the standard named in the requirement, then verify that the specimen and equipment configuration match it. ASTM D256 and ISO 180 are relevant references for Izod impact testing, but they should not be treated as interchangeable without checking the requirement.
The Charpy Impact Testing Machine is a related product category, but a Charpy setup is not a substitute for an Izod setup just because both use a pendulum. Confirm the test method and required fixture before selecting equipment.

What the Izod test measures and why it is used

An Izod impact test measures how much impact energy a notched specimen absorbs during a pendulum strike, providing an indication of the material’s resistance to impact fracture under the specified test conditions.
This result helps compare material behaviour when a sudden blow is relevant to evaluation or quality control. For example, a laboratory may test a material against a specification or compare specimens prepared and tested under the same method. The result is useful in that defined context; it does not by itself describe every aspect of a material’s performance in service.
A notch concentrates stress at a defined location, helping make the test response more consistent than an impact on an unnotched specimen. The method still depends on the details set by the chosen standard, including the specimen and test conditions. Results from different materials or procedures should not be compared as though only the material changed.
When reviewing an Izod and Charpy impact test, distinguish the shared purpose—assessing response to impact—from the different specimen arrangements. A difference in support or impact orientation changes the test setup, so it can affect whether a result is relevant to a particular requirement.
How the Izod specimen and pendulum test are arranged

In a typical Izod arrangement, the notched specimen is held vertically as a cantilever, with the pendulum striking it at the specified location relative to the notch. The selected standard determines the precise specimen and procedure details.
The general sequence is:
- Prepare a specimen that matches the required material, dimensions and notch specification.
- Clamp it in the Izod fixture in the prescribed vertical orientation.
- Position the notch and impact face as required by the selected method.
- Release the pendulum so it strikes the specimen.
- Record the absorbed impact energy and any other observations required by the procedure.
The notch direction matters because it determines how the pendulum loads the specimen in relation to the notch. Do not rely on a verbal label such as “notch facing forward”; confirm the orientation against the applicable standard or laboratory procedure and the fixture instructions.
Specimen dimensions, notch geometry, conditioning and other procedural details must also follow the relevant standard. They are not safe to infer from a general description of the method. If a laboratory is adopting a new procedure, it should document which method is being followed and how the specimen is prepared and mounted.
How to interpret and report Izod impact results
An Izod result is based on the energy absorbed by the specimen during impact; reporting should identify the method and specimen details needed to interpret that energy correctly.
The machine’s indicated absorbed energy is not meaningful in isolation. The report should state the material identification, applicable standard and method, specimen identification and relevant preparation or test conditions required by that procedure. Include the result in the units and form required by the standard; where the method calls for an impact-strength value derived from absorbed energy and specimen dimensions, report that value as specified.
Keep the distinction between absorbed energy and impact strength clear. Absorbed energy describes the energy taken up in the test, while an impact-strength result may express energy relative to a specimen dimension or area as defined by the method. Do not convert or label a reading using an assumed formula: use the calculation and reporting rules in the selected standard.
When comparing results, check that the specimens and procedures are comparable. A change in notch, specimen preparation, conditioning, fixture arrangement or test method can make a direct comparison misleading. For an overview of calculating impact-test energy and results in the Charpy context, see how Charpy impact results are calculated.
How Izod and Charpy methods differ
Both methods use a pendulum to impact a notched specimen, but Izod typically holds the specimen vertically as a cantilever, while Charpy supports a horizontal specimen across a span.
| Criterion | Izod | Charpy |
|---|---|---|
| Specimen arrangement | Typically vertical and clamped at one end | Typically horizontal and supported at both ends |
| Support | Cantilever-style fixture | Two-support arrangement |
| Impact relationship | The pendulum strikes the vertically held specimen as prescribed by the method | The pendulum strikes the specimen in its supported span as prescribed by the method |
| Selection basis | Use when the material requirement specifies an Izod method | Use when the material requirement specifies a Charpy method |
These are method-level distinctions, not a rule that one test is universally preferable. The applicable material specification decides which method is relevant. A “Charpy and Izod test” comparison is useful for identifying the setup, but it does not make results from one method interchangeable with results from the other.
For a more focused comparison of the two methods, see the Charpy and Izod test comparison. If your work concerns Charpy specimen dimensions, this guide to minimum Charpy specimen thickness addresses that separate requirement.
What to verify on an Izod impact tester
Before selecting or using an impact tester, verify that its pendulum, fixture and measurement arrangement suit the specified method and specimen.
Use this checklist when discussing a machine with an equipment supplier or laboratory:
- Confirm the exact standard and method required by the material specification.
- Match the specimen dimensions and notch requirements to the fixture.
- Confirm that the fixture holds the specimen in the required orientation and allows the specified impact arrangement.
- Check that the pendulum configuration and energy range suit the expected test requirement.
- Ask how the machine’s indicated energy is calibrated or verified and what records are available.
- Confirm how results are displayed, recorded and reported for your procedure.
- Agree on the specimen preparation and mounting process, including operator training needs.
- Document the accepted machine configuration and fixture details so the delivered setup can be checked against the agreed specification.
A machine description alone may not settle whether a setup meets your method. Ask for the configuration and fixture details in writing, and compare them with the test procedure before purchase or commissioning. The same discipline applies when replacing equipment: verify the agreed specification against the supplied machine and its accessories before routine testing begins.
Frequently Asked Questions (FAQ)
How is the Charpy impact test done?
A notched specimen is typically placed horizontally on two supports, then struck by a pendulum; the machine records the energy absorbed under the specified Charpy procedure.
Why do we do the Izod impact test?
The Izod test assesses a material’s resistance to impact fracture by measuring energy absorbed when a pendulum strikes a notched specimen held in the prescribed fixture.
What is the ASTM standard for impact testing?
ASTM D256 is a key standard for Izod impact testing of plastics. The required method depends on the material specification and the test requirement.
What is the difference between Charpy and Izod test?
The main setup difference is specimen orientation and support: Izod typically uses a vertical cantilever specimen, while Charpy typically uses a horizontal specimen supported at both ends.
Choose the standard and setup for your test requirement
To identify the right method, work from the material requirement to the specimen, fixture and machine configuration rather than choosing by the test name alone.
- Read the material specification or quality procedure and record the required impact-test standard.
- Confirm whether the requirement calls for ASTM D256, ISO 180 or another specified method.
- Check the prescribed specimen, notch, preparation and test conditions against the procedure.
- Select an Izod or Charpy arrangement that matches the required method and specimen support.
- Compare the machine, pendulum, fixture, measurement and calibration documentation with the agreed test setup.
- Record the accepted configuration and reporting requirements before testing begins.