The difference between the Charpy and Izod impact test is how the notched specimen is held and struck: Charpy uses a horizontal, simply supported specimen, while Izod holds the specimen vertically as a cantilever. Both tests measure absorbed impact energy, but their results are not directly interchangeable because the specimen and test configuration differ.
What is the difference between Charpy and Izod impact tests?

Charpy and Izod both measure the energy absorbed when a pendulum breaks a notched specimen; they differ chiefly in specimen support, notch orientation, and the striker’s position and direction.
| Comparison point | Charpy test | Izod test |
|---|---|---|
| Specimen position | Horizontal | Vertical |
| Support | Supported at both ends as a beam | Clamped at one end as a cantilever |
| Notch orientation | The notch is on the side opposite the striker’s contact face in the usual configuration | The notch faces the striker in the usual configuration |
| Striker position | Strikes the specimen between its supports, opposite the notch | Strikes above the clamp, at a specified position relative to the notch |
| Impact direction | Across the span of the supported specimen | Toward the exposed, clamped specimen |
The table describes the common arrangements, not every permitted specimen or setup. The standard selected for the material defines the specimen dimensions, notch details, support or clamp geometry, striker location, and other test conditions. Those details must be checked before testing or comparing reported values.
For a Charpy and Izod test comparison, the setup is central: changing the support arrangement changes how the specimen responds to the pendulum blow. Notch orientation and striker location also affect the fracture response. A result is meaningful only alongside the method and configuration used to obtain it.
“Notch orientation” describes the notch’s position relative to the striker and specimen support. The test standard specifies this arrangement; an operator should not assume that a sample prepared for one method can be placed in the other method’s fixture without checking its requirements.
What do the impact energy values tell you?

Impact energy is the energy a specimen absorbs during fracture under the specified test conditions; the Charpy value is the absorbed energy recorded for that test, not a universal material rating.
A pendulum has a known potential energy at its starting position. After it strikes and fractures the specimen, it rises to a lower height because some of its energy was absorbed during the impact. In simplified terms:
Absorbed impact energy = pendulum energy before impact − pendulum energy after impact
The reported value is commonly expressed in joules, though reporting requirements and units should be confirmed against the applicable method and equipment. The energy reading describes the test outcome for that specimen and setup. It does not, by itself, establish how a material will behave in every impact situation.
When interpreting results, read the value together with the material, specimen dimensions, notch, test method, and any other conditions required for the report. For example, two reports may both state absorbed energy in joules but refer to different specimen geometries or test methods. The shared unit does not make their results equivalent.
A Charpy value indicates the absorbed energy for the Charpy specimen tested under its stated conditions. It is not the same as tensile strength, hardness, or fatigue limit. For background on interpreting a Charpy result, see our guide to calculating Charpy impact energy. If specimen size is a concern, consult the guide to Charpy specimen thickness.
Which standards apply to Charpy and Izod testing?
Applicable standards depend on both the test method and the material; ASTM E23 covers metallic-material impact testing, while plastics use separate Charpy and Izod methods.
For metallic materials, ASTM E23 is the relevant ASTM method for notched-bar impact testing, including Charpy testing. ISO methods also specify requirements for particular materials and procedures, so the applicable edition and scope should be confirmed for the material and test being performed.
For plastics, ASTM D6110 covers Charpy impact testing, and ASTM D256 covers Izod impact testing. ISO also has separate plastics impact-test methods for Charpy and Izod arrangements. A laboratory should identify the relevant ISO method and edition from its governing specification rather than assume that an ASTM method and an ISO method are interchangeable.
The standard’s scope matters as much as its name. Confirm that it applies to the material, specimen type, notch, and procedure required by the customer, product specification, or laboratory method. For example, a plastics method should not be selected to report a metallic-material result.
The same principle applies when selecting equipment. A machine’s description alone does not establish that it supports a particular standard or configuration. Check the method’s requirements against the machine’s documented setup, available fixtures, and reporting needs.
How do you choose the right test and compare results?
Choose the method required by the material specification or governing standard, then compare results only when the specimens and test configurations match the relevant requirements.
Start with the material and the purpose of the test. A product specification may call for a particular method, specimen, or reporting format. If it does, follow that requirement rather than choosing Charpy or Izod solely because one setup is familiar or available.
Next, compare the full test definition, not just the method name or energy value. Check:
- Material and applicable standard, including its edition.
- Specimen dimensions and whether the specimen meets the method’s requirements.
- Notch geometry and orientation.
- Support or clamping arrangement.
- Striker position and impact direction.
- Required units and report details.
These checks explain why values from Charpy and Izod tests should not be treated as directly interchangeable. The methods use different specimen support and impact arrangements, and the specimen and notch details may also differ. A numerical result in joules cannot remove those differences.
When two reports appear to conflict, first check whether they used the same method, material, specimen geometry, notch, and test conditions. If any of these differ, the results describe different test configurations; they do not establish a like-for-like comparison. For a laboratory or quality-control procedure, have the responsible technical authority confirm the method and interpretation required for that application.
How should you choose the test method for your material?
Select the method named in the material or product requirement, then verify that the specimen, notch, fixture, test configuration, and report all follow that method.
For a purchasing or laboratory decision, request the method and specimen details before comparing equipment or test results. If a machine is being evaluated, compare the documented test configuration and fixtures with the standard requirements. Also confirm how results will be recorded and whether the report includes enough information to identify the method and specimen used.
These checks help distinguish a meaningful comparison from two numbers that only look comparable. The method determines what the result represents; the material specification or testing requirement determines which method is appropriate.
Frequently asked questions
Which material property is measured during a Charpy impact test?
A Charpy test measures impact energy: the energy absorbed as a notched specimen fractures under the specified test conditions. It does not measure tensile strength, hardness, or fatigue limit.
What is the Izod and Charpy test?
They are pendulum impact tests that measure energy absorbed when a notched specimen fractures. Charpy supports the specimen at both ends; Izod clamps it at one end.
What is the ASTM standard for the Charpy impact test?
ASTM E23 covers notched-bar impact testing of metallic materials, including Charpy testing. For plastics, ASTM D6110 is the Charpy impact method; confirm the scope that fits the material.
How do you calculate Charpy impact test energy?
Subtract the pendulum’s energy after impact from its energy before impact. The resulting absorbed energy is reported according to the applicable method and required units.
Who invented the Charpy test?
The test is named after Georges Charpy, a French engineer associated with its development. For current testing, the governing standard and specimen requirements matter more than the historical origin.
Take these steps before selecting a method
- Identify the material and the specification or testing requirement that governs its impact test.
- Confirm the applicable standard, edition, and material scope with the responsible technical authority.
- Check the required specimen dimensions, notch, orientation, support, striker position, and impact direction.
- Compare results only when the method and relevant specimen and test conditions are aligned.
- Record the method, specimen details, units, and required test conditions with each reported impact-energy value.